Appendix B Temperature and
Current Limits
The range of temperature, heater currents, currents and ground/earth leakage are
tabulated in the below list.
Parameters Limits
TEMPERATURES All circuit temperature set points for the TCM18
should be programmed with the following limits:
MinTemp <= LTA < MT <
(MT + CB) < HTA <= HTT <= MaxTemp
MinTemp = -200
F (-128
C)
LTA = Low Temp Alarm
MT = Maintain Temp
CB = Control Band
HTA = High Temp Alarm
HTT = High Temp Trip (or HHAlarm)
MaxTemp = 1112
F (600
C)
75 PN 50316_0514